 SENSITRON SEMICONDUCTOR
TECHNICAL DATA Datasheet 4165, Rev. B
SPM6G060-120D
Three-Phase IGBT BRIDGE, With Gate Driver and Optical Isolation
DESCRIPTION: A 1200 VOLT, 60 AMP, THREE PHASE IGBT BRIDGE
ELECTRICAL CHARACTERISTICS PER IGBT DEVICE
(Tj=250C UNLESS OTHERWISE SPECIFIED) SYMBOL MIN TYP MAX UNIT
PARAMETER
IGBT SPECIFICATIONS
Collector to Emitter Breakdown Voltage IC = 500 A, VGE = 0V Continuous Collector Current TC = 25 OC
O
BVCES IC ICM VGE IGES ICES
1200 -
-
60 40 100 +/-20 +/- 200
V A A V nA
TC = 90 C Pulsed Collector Current, Pulse Width limited by TjMax Gate to Emitter Voltage Gate-Emitter Leakage Current , VGE = +/-20V Zero Gate Voltage Collector Current VCE = 1200 V, VGE=0V Ti=25oC VCE = 800 V, VGE=0V Ti=125oC Collector to Emitter Saturation Voltage, IC = 40A, VGE = 15V, Maximum Thermal Resistance Maximum operating Junction Temperature Maximum Storage Junction Temperature Tj = 25 C Tj = 125 C
O O
1 10 VCE(SAT) 1.9 2.1 RJC Tjmax Tjmax -40 -55 2.3 0.6 150 150
o
mA mA V
C/W
o o
C C
* 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 1 of 6
SPM6G060-120D SENSITRON TECHNICAL DATA Datasheet 4165, Rev. B
Over-Temperature Shutdown
Over-Temperature Shutdown Over-Temperature Output Over-Temperature Shutdown Hysteresis Tsd Tso 90 100 10 20 115
o
C
10mV/oC
o
C
ULTRAFAST DIODES RATING AND CHARACTERISTICS
Diode Peak Inverse Voltage Continuous Forward Current, TC = 90 C Forward Pulse Current, Pulse Width limited by TjMax Diode Forward Voltage, IF = 40A, Tj = 25 C Tj = 125 OC Diode Reverse Recovery Time (IF=40A, VRR=600V , di/dt=800 A/s) Maximum Thermal Resistance
O O
PIV IF IFp VF
1200 -
1.8 1.8
40 100 2.3
V A A V
trr RJC
-
240 -
1.0
nsec
o
C/W
Gate Driver
Supply Voltage Input On Current Opto-Isolator Logic High Input Threshold Input Reverse Breakdown Voltage Input Forward Voltage @ Iin = 5mA Under Voltage Lockout ITRIP Reference Voltage
(1)
VCC HIN, LIN Ith BVin VF VCCUV Itrip-ref tond tr toffd tf -
10 2 5.0 11.5 2.5 -
15
20 5.0
V mA mA V V V V nsec
1.6 1.5 2.6 TBD TBD TBD TBD
1.7 12.5 2.7 -
Input-to-Output Turn On Delay Output Turn On Rise Time Input-to-Output Turn Off Delay Output Turn Off Fall Time @ VCC=400V, IC=40A, TC = 25 Input-Output Isolation Voltage
1500
-
-
V
(1) ITRIP Cycle-by cycle current limit is internally set to 43A peak. The set point can be lowered by connecting a resistor
between Itrip-ref and Gnd. The set point can be increased by connecting a resistor between Itrip-ref and +5V ref
* 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 2 of 6
SPM6G060-120D SENSITRON TECHNICAL DATA Datasheet 4165, Rev. B
Pin Description
Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Function Isolated Input for High-side IGBT of Phase A Return for Input at 1 NC Isolated Input for Low-side IGBT of Phase A Return for Input at 4 NC Isolated Input for High-side IGBT of Phase B Return for Input at 7 NC Isolated Input for Low-side IGBT of Phase B Return for Input at 10 Isolated Input for High-side IGBT of Phase C Return for Input at 12 Isolated Input for Low-side IGBT of Phase C Return for Input at 14 NC NC Pin Number 18 19 20 21 22 23 24 25 26 27 28 &29 30 & 31 32 & 33 34 & 35 36 & 37 Case Function NC +15V Input +15V Rtn (Signal Ground) SD
(3) (3)
Fault Output
(3) (3)
Fault Clear Input +5V Output
Over-Current Trip Set Point
(3)
DC Bus Current Output with Total Gain of 0.06 V/A Case Temperature Output with Gain of 0.010 V/oC Phase A Output Phase B Output Phase C Output DC Bus "+VDC Return" DC Bus "+VDC" Input Isolated From All Terminals
* 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 3 of 6
SPM6G060-120D SENSITRON TECHNICAL DATA Datasheet 4165, Rev. B
Package Drawing Top View (All dimensions are in inches, tolerance is +/- 0.010")
3.05
* 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 4 of 6
SPM6G060-120D SENSITRON TECHNICAL DATA Datasheet 4165, Rev. B
Package Pin Locations (All dimensions are in inches; tolerance is +/- 0.005" unless otherwise specified)
* 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 5 of 6
SPM6G060-120D SENSITRON TECHNICAL DATA Datasheet 4165, Rev. B Application Notes: a- Shutdown Feature: 1- Pin 21, SD, is a dual function input/output, active low input. It is internally pulled high. As a low input, it shuts down all IGBTs regardless of the Hin and Lin signals. 2- SD is also internally activated by the over-temperature shutdown, over-current limit, undervoltage shutdown, and desaturation protection. 3- Over-temperature shutdown, and over-current limit are not latching features. 4- Under-voltage shutdown is automatically reset once the VCC rises above the 12.1V threshold limit. 5- Desaturation shutdown is a latching feature and internally reset. 6- When any of the internal protection features is activated, SD is pulled down. 7- SD can be used to shutdown all IGBTs by an external command. An open collector switch shall be used to pull down SD externally. 8- Also, SD can be used as a fault condition output. Low output at SD indicates a fault situation. b- Fault Output Feature: 1- Pin 22, Flt is a dual function pin. It is internally pulled high. If pulled down, it will freeze the status of all the six IGBTs regardless of the Hin and Lin signals 2- Pin 22 as an output reports desaturation protection activation. When desaturation protection is activated a low output for about 9 sec is reported. 3- If any other protection feature is activated, it will not be reported by Pin 22. c- Fault Clear Output: 1- Pin 23, Flt-Clr is a fault clear input. It can be used to reset a latching fault condition, due to desaturation protection. 2- Pin 23 is internally pulled down. A latching fault due to desaturation can be cleared by pulling high this input. 3- An internal fault clear is activated after 100 sec delay. If desired to clear the fault earlier, this input can be used. d- Signal Ground: Pin 20, Signal Gnd is a the signal ground for all signals at Pins 19 through 27. This ground is internally connected to the +VDC Rtn. No external connection shall be established between Signal Gnd and +VDC Rtn.
* 221 West Industry Court Deer Park, NY 11729 (631) 586 7600 FAX (631) 242 9798 * * World Wide Web Site - http://www.sensitron.com * E-mail Address - sales@sensitron.com * Page 6 of 6


▲Up To Search▲   

 
Price & Availability of SPM6G060-120D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X